Windows / French Windows

SAPA 1086

Screen Window

Windows with frame specially developed for integrated screen

Characteristics

SAPA in collaboration with Hunter Douglas offers an integrated screen solution that gives a slim and fine impression. A solution where the screen roller is mounted hidden in the frame. SAPA 1086 Screen is based on our 86 system, a stable construction with 86 mm deep profiles. It is basic insulated with 42 mm fiberglass-reinforced polyamide strips and can withstand the highest classes of air and rain tightness as well as a very low U-value. For optimal energy performance, it can be supplemented with unique insulating bars. SAPA 1086 Screen has rebate for glass 20-56 (64) mm.

This product is made of Hydro CIRCAL® recycled aluminum. Read more here

This product is made of Hydro REDUXA® - Aluminum produced from renewable energy. Read more here

Special developed frame for installation of the screen. For information regarding the screen please contact Hunter Douglas. Contact info : post@hunterdouglas.no

Documentation
SAPA 1086 EN
SAPA 1086 Screen
SAPA 1086 SCREEN_ Vävduk_HunterDouglasSerge_3_gme_2018-2021.pdf
SAPA 1086 SCREEN_Vävduk_HunterDouglas_SOLTIS Perform 92.pdf

Product benefits

DIVERSITY OF APPLICATIONS

  • Single window, meeting windows or as an element combining opening and a fixed window
  • Fittings. Side, bottom, top-hung or tilt and turn
  • Hinges. Hidden or visual

HIGH PERFORMANCE

  • U-value. Down to 0,8 W/m²K (PX, inward opening Ug=0,5 W/m²K, dimension 1230x1480 mm)
  • Sound reduction. Up to Rw 45 dB
  • Max sash weight: 200 kg

HIGH PERFORMANCE

  • Air-permeability. Class 4 according to EN 12207
  • Water tightness Class 9A according to EN 12208

HIGH PERFORMANCE

  • Resistance to wind load: Class C3 according EN 12210
  • To withstand the wind load the screen will be guided in vertical guide profiles.

More information

Specifications & EPD

Fitting functions

Top-hung, inward opening

Closed

Open, top-hung

Notter AL 18 closing fittings alt concealed hinges Notter AL18 VDL
x6661259 handle
x6661261 lockable handle
Sapa S16439 handle
Sapa S16439 handle with S16441 child safety lock
Sapa S16438 lockable handle


Tilt and turn, inward opening

Closed

Ventilation, bottom-hung

Open, side-hung

Notter AL 18 closing fittings alt concealed hinges Notter AL18 VDL
x6661259 handle
x6661261 lockable handle
Sapa S16439 handle
Sapa S16439 handle with S16441 child safety lock
Sapa S16438 lockable handle

Side-hung, inward opening

Closed

Open, side-hung

Notter AL 18 closing fittings alt concealed hinges Notter AL18 VDL
x6661259 handle
x6661261 lockable handle
Sapa S16439 handle
Sapa S16439 handle with S16441 child safety lock
Sapa S16438 lockable handle


Bottom - hung, inward opening

Closed

Open, bottom-hung

Notter AL 18 closing fittings
x6661259 handle
x6661261 lockable handle
Sapa S16439 handle
Sapa S16439 handle with S16441 child safety lock
Sapa S16438 lockable handle

Handle

Aluminium handle
Art.no.: Sapa 16439

Aluminium handle with child safety lock
Art.no.: Sapa 16439 Child safety lock Sapa 16441

Lockable aluminium handle
Art.no.: Sapa 16438

Aluminium handle
Art.no.: Sapa 16126

Lockable aluminium handle
Art.no.: Sapa 16131



Window location in structure

For the entire window structure to meet the energy saving requirements and ensure good comfort it is necessary to install the window in the warm part of the wall. This means that it should be installed as deep into the wall as possible, which has a number of advantages.

It creates good conditions for appropriate fixing and a well functioning joint. The risk of condensation is reduced due to a higher surface temperature. The joint between the frame profile and the wall shall be made with two step sealing. This means that it should consist of an outer rain barrier with an underlying air channel, a mineral wool insulation layer and an inner diffusion sealing joint.

Connections, see Elevations and details in the left hand menu.

Glazing

Unprotected glazed surfaces that can be reached by persons shall be designed so as to limit the risk of injury. Such glazed surfaces shall be dimensioned so as to withstand the dynamic influence of a person. Applicable standards and requirements should be taken into account.

Functional dimensions
Glass thickness: 1086 and 1086 SX 20-56 (64) mm, 1086 PX 35-55 mm.



The illustration shows the different functional dimensions commonly used by the window industry and established by the MTK. The gaskets are made of EPDM rubber and are available in several versions.

Fixing Principles

Fixing principles

Windows must be fixed to a stable and suitable wall structure. The choice of fixing method depends on the wall type. The number and location of fixing points depends on the size of the window.

Exemple:

Fixing of frame with
twist anchor

Fixing of frame with
adjustable frame bushing

Fixing of frame with
bolt and welded plate

Projects using windows / french windows SAPA 1086

Tramway, Lund

Sweden

Developer: Region Skåne / Lunds Kommun
Construction contractor: NCC Building Sweden
Metal builder: Alab Aluman AB
SAPA solutions: Facade 4150, Doorr 2086, Window 1086