Facades / roof glazing

SAPA 5050

Roof Glazing

Roof and slooped glazing with freedom of design

Characteristics

SAPA 5050 roof glazing system consists of 50 mm wide insulated aluminium profiles. The system has a longitudinal insulating strip which provides good insulation and support for the glass holders. The horizontal, vertical and dividing profiles come in different depths. Rebate for single glass or for double and triple glazing units.

The 5050 system makes it possible to give the roof virtually any form. Glazed roofs can have large spans without compromising the static stability.

SAPA 5050 roof glazing is also available in an uninsulated version with a single glass rebate.

Documentation
5050_EN_ProdBrochure2021.pdf

Product benefits

DIVERSITY OF APPLICATIONS

  • Inclination. Recommended at least 15°
  • Roof lights for comfort ventilation and smoke evacuation

LARGE SIZES

  • Insulated or uninsulated profiles
  • Profile width. 50 mm
  • Profile depth. Vertical: 60-180 mm, horizontal: 25-138 mm

LARGE SIZES

  • Vertical dividing profiles. Width 50 mm
  • External glass holders. 7 mm for stability and good water runoff

More information

Specifications & EPD

Ventilation roof lights

For ventilation roof lights are combined with smoke evacuation function. For the best results, the roof lights should be located as high as possible in the glazed roof. The number of opening units should be calculated for both comfort and smoke ventilation. For adjustment, the roof lights should be equipped with automatic devices and motorised drive.

Ventilation / smoke hatch SAPA 5050 Roof Vent is developpted for fully integration in Sapa glass roofs / facades. The hatch is well integrated into the facade profiles and lies more flat than previous products. The ventilation hatch is certified for smoke ventilation and optimal for projects with fire safety requirements. The hatch has a good insulation value with the possibility of using tripple glas units.

Glazing

Glazed roofs shall be designed to prevent accidents resulting from fall or stepping through. Normally, toughened glass is used as the outside layer and laminated glass as the inside layer. Applicable standards and requirements should be taken into account.

44-51 mm tripple glazing units
24-35 mm double glazing units
6-11 mm single glazing





G= Glass rebate

Elevations And Details

A5050-1006 110111213141516171819233132333435363738456789
Save this elevation as: dwg / dxf
Click on number to view the details
A5050-1007 11011131516172331323334353637384567
Save this elevation as: dwg / dxf
Click on number to view the details
A5050-1003 101323331323334
Save this elevation as: dwg / dxf
Click on number to view the details
A5050-1009 10111314202122331343537385789
Save this elevation as: dwg / dxf
Click on number to view the details